11/4(水)の問題
目標解答時間
8:07
共通テスト2026英語リーディングを75分で解ききるために必要な読解ペースを元に算出しています。
設問
4 問
一時停止
いつでもOK
解説・和訳は、結果をアプリに引き継ぐと読めます。
2026年11月4日・記事
共通テスト 英語リーディング 練習問題「Ancient Architecture and Modern Cooling」
2026年11月4日に配信した、本番と同じ形式のオリジナル問題です(全4問)。 上の「解答スタート」を押すと、時間を計って解けます。
英文と設問を先に見る(タイマーなし)英文と設問を閉じる
A student wrote the following summary draft after reading the article. Read the draft and the teacher's comments.
In regions where summer temperatures frequently exceed forty degrees Celsius, communities throughout history developed ingenious architectural methods to keep living spaces comfortable without relying on electric power.
Among the most remarkable of these historic innovations is the windcatcher, a tall chimney-like tower that has been used for centuries across dry areas of the Middle East and North Africa.
Positioned high above ordinary rooftops, these towers capture the faster, cooler breezes that circulate well above the dusty street level and channel the fresh airflow downward into the rooms below.
As this cool air enters the residence, warmer air naturally rises due to convection and escapes through exhaust vents on the opposite side of the building, establishing a steady and refreshing circulation.
In particularly dry areas, builders even directed the incoming current across underground water channels, using the natural principle of evaporative cooling to lower indoor temperatures by several additional degrees.
Performance Comparison of Building Cooling Strategies
| Cooling Method | Energy Requirement | Indoor Temp Reduction | Water Dependency |
|---|---|---|---|
| Conventional Air Conditioning | Very High | 10–14°C | None |
| Evaporative Air Cooler | Moderate | 5–8°C | High |
| Passive Windcatcher Tower | None | 4–7°C | None |
| Hybrid Tower with Water Channel | Low (pumps only) | 8–12°C | Moderate |
Today, environmental engineers are reviving these ancient concepts to combat the surging power consumption caused by modern motorized air-conditioning systems.
A prominent showcase of this revival is a recently completed public library in southern Spain, which features four modern wind shafts connected to subterranean air ducts.
Throughout its first full summer of operation, the facility maintained pleasant indoor conditions while consuming less than one-quarter of the electricity used by neighbouring civic buildings of comparable size.
Specialists note that although local weather patterns and high construction accuracy dictate how effectively these structures perform, passive ventilation presents a promising path toward zero-emission urban development.
Student Summary Report Draft
The windcatcher is an ancient architectural invention designed to ventilate buildings naturally. By capturing high-altitude air and releasing hot air through separate openings, it keeps rooms cool without electricity. <1> Modern architects are now adapting this technique. For example, a new library in Spain used more electricity than nearby buildingsA during the summer. <2> Overall, passive cooling demonstrates that traditional knowledge can help modern cities lower their environmental impact.
Comments
Mr. Davies
The passage also explained how underground water was used in especially dry climates to improve cooling. You should add that detail right after explaining the basic air circulation.
Check the facts in the library example. The text actually said it used much less power than comparable municipal facilities.
1. According to the passage, how does a traditional windcatcher maintain airflow inside a house?
- (A) By drawing in warmer air from street level to push cooler breezes outdoors
- (B) By trapping outdoor air inside closed rooms so heat cannot enter through the roof
- (C) By directing higher-level breezes downward while warmer indoor air exits from other vents
- (D) By using motorized fans to force warm air underground toward cold water channels
2. Based on the passage and the table, which of the following is true regarding cooling systems?
- (A) Passive windcatcher towers require high amounts of water to achieve any cooling effect.
- (B) Hybrid towers achieve greater temperature reduction than standard passive windcatchers while requiring far less energy than conventional air conditioning.
- (C) Evaporative air coolers consume more electricity than any other cooling method listed.
- (D) Conventional air conditioning achieves the lowest indoor temperature reduction among all systems.
3. The student wants to insert the following sentence into the draft based on Mr. Davies's comment: "In desert settings, indoor temperatures were lowered even further by directing the airflow across underground water." Where is the best place to add this sentence?
- (A) <1>
- (B) <2>
- (C) Right before the first sentence of the draft
- (D) Right after the final sentence of the draft
4. Which is the best way to rewrite the underlined part "used more electricity than nearby buildings" to correct the factual error?
- (A) required more maintenance work than standard facilities
- (B) relied entirely on fossil fuels to run its cooling fans
- (C) consumed significantly less power than similar civic structures
- (D) generated excess clean electricity for the surrounding community
正解と解説は、上の「解答スタート」から解いて提出すると見られます。